Update for CI2 initial condition

All,

We have posted a minor correction to the initial condition for the CI2 inviscid strong vortex interaction test case. We made the following change regarding the initial condition: the definition of u from the originally defined value of 1.775 (round off value) to an alternative derived equation (equation is described in the pdf-file). Using the original initial condition may produce a negligible error, but we would like to define it as a more accurate value. We have also updated the python script with the equation.

Hopefully everyone interested in test case is able to use these new initial conditions. Please let me know if you have any questions.

Thank you,

Marshall Galbraith